Specialty Power Solutions
Home » Products » Accessories » Power » Specialty Power Solutions

GEIST-logo
Geist is a US manufacturer of customized power distribution solutions for racks and cabinets. With the broadest selection in the industry, Geist offers over 1000 model numbers made up of numerous product configurations and options. All model numbers are built to order, allowing customers to build a PDU to fit their specific needs; these customized PDUs are still able to be pre-installed in Great Lakes enclosures.

NSVBCN200-102S20TL
PDU with Local Digital Read-Out
RBRCN100-102STL 20 AMP, 125V, L5-20P, 10 x 5-20R on rear, 10′ cord, 1U rack mount,
1.72″H x 17.00″W x 4.50″D; Digital power meter displays amps, volts,
watts and power factor.
NSVBCN200-102S20TL 20 AMP, 125V, L5-20P, 20 x 5-20R on rear, 10′ cord, vertical mount,
66.25″H x 1.61″W x 1.61″D; Digital power meter displays amps, volts,
watts and power factor. (pictured above)
Note: 72″H E Series enclosure can accept a maximum of 59″H power strips
RSPRN122-00C13C20-#1-FRONTRSPRN122-00C13C20-BACK
RacSense
RacSense® Power solutions feature power distribution units with remote power monitoring and
alarming. Monitors voltage, current, real power, apparent power & power factor.
RSPRN122-00C13C20 20 AMP, 125 or 250V, C20 power inlet (cord required), 12 x C-13
1U rack mount, 1.72″H x 17.00″W x 4.50″D (pictured above)
RSPBN302-102IN6TL5 20 AMP, 125V, L5-20P, 24 x C-13/6 x C19, 10′ cord, vertical mount,
66.25″H x 2.00″W x 2.00″D
Note: 72″H E Series enclosure can accept a maximum of 59″H power strips
RSMB300-103IN6TL5--3
RacSense Master
RacSense® Master units combine power distribution, power/environmental monitoring, and remote
alarming together in one solution. Environmental monitoring via three I/O ports or using four RJ12 ports.
RSMRN122-002C13C20 20 AMP, 125 or 250V, C20 power inlet (cord required), 8 x C-13,
1U rack mount, 1.72″H x 17.10″W x 8.50″D (connect optional remote
sensors via 2 x RJ jacks) (pictured above)
RSMB300-103IN6TL5 20 AMP, 125V, L5-20P, 16 x 5-15R, 10′ cord, vertical mount, 66.25″H x
3.10″ W x 2.00″D (connect optional remote sensors via 2 x RJ jacks)
Note: 72″H E Series enclosure can accept a maximum of 59″H power strips
RCURN082-002C13C20RCURN082-002C13C20-Back-View
RacSense Control Ultra
RacSense® Control Ultra distribution units deliver individual on/off outlet control, receptacle level current
monitoring, user defined alarm thresholds and real-time remote alarming.
RSURN082-002C13C20 20 AMP, 125 or 250V, C20 power inlet (cord required), 8 x C-13,
1U rack mount, 1.72″H x 17.10″W x 8.50″D (connect optional remote
sensors via 2 x RJ jacks) (pictured above)
RCUBN162-102S15TL5 20 AMP, 125V, L5-20P, 16 x 5-15R, 10′ cord, vertical mount, 66.25″H x
3.10″ W x 2.00″D (connect optional remote sensors via 2 x RJ jacks)
Note: 72″H E Series enclosure can accept a maximum of 59″H power strips

RS-Mini
RacSense Control Ultra
Monitors up to 16 remote environmental sensors with a unit the size of a candy bar. This compact and powerful unit displays the same user interface, including graphs, as the
RacSense product line. Ideal for discrete placement in tight locations.
RSMINI Mini Environmental Monitoring Unit to be used with the following parts:
RT12 Temperature Sensor, 12′ cord (RJ)
RTAF12 Temperature and Airflow Sensor, 12′ cord (RJ)
RTAFH12 Temperature, Airflow, and Humidity Sensor, 12′ cord (RJ)
RTHD12 Temperature, Humidity, and Dew Point Sensor, 12′ cord 9RJ)
RCP2 City Power Monitor
SA-1 Smoke Alarm Kit (I/O)
RWS Water Sensor, 20′ cord (I/O)
SP-5 RJ12 5 Way Splitter
CCAT I/O to RJ Remote Sensor Convertor

EATON_LOGO2_003

With today’s rapidly evolving information technology and equipment—and 99.999% system availability requirements—data center IT managers need increasingly sophisticated power distribution solutions. Eaton® offers the largest selection of enclosure power distribution solutions on the market, including the Eaton ePDU™ product family. ePDUs are specifically designed to provide maximum flexibility and reliability in distributing power throughout modern data centers. They enable primary power distribution from the UPS to secondary power distribution devices or directly to IT equipment, for organized power distribution with fewer cables to manage and fewer distribution points to monitor.

Features and Benefits
• Data center- and server-level power measurement and control
• Basic, Monitored, Advanced Monitored and Switched models available to provide exactly the desired level of control
• High-density models for power-hungry IT equipment including blade servers and switches
• Vertical 0U or rack mount 1U/2U configurations for flexible installation
• Configurable combinations of NEMA, IEC and hardwired input connections, and NEMA and IEC output receptacles
• Circuit breaker or individual outlet fusing options
• Rugged, industrial-grade construction
• Wall, floor and rack mounting options
• North American and international configurations available
• Custom designs available on request
• Designed to meet global safety standards including UL and CE

Basic
Basic ePDU
• Reliable and economical enclosure power distribution
• Vertical and horizontal mounting capabilities
PW102BA1U159 1.92 kW, L5-20P, 12 x 5-20R, 9′ cord, 1U rack mount,
1.80″H x 19.00″W x 7.00″D, 120V
PW105BA1U192 4.99 kW, L6-30P, 6 x C13/4 x C19, 9′ cord, 1U rack mount,
1.80″H x 19.00″W x 7.00″D, 208V
PW102BA0U021 1.92 kW, L5-20P, 24 x 5-20R, 15′ cord, vertical mount,
60.00″H x 2.10″W x 1.30″D, 120V
PW105BA0U239 4.99 kW, L6-30P, 24 x C13/4 x C19, 9′ cord, vertical mount
66.00″H x 1.90″W x 2.00″D, 208V
PW306BA0U244 5.86 kW, L21-20P, 30 x C13/6 x C19, 9′ cord, vertical mount
66.00″H x 1.90″W x 2.00″D, 3 phase WYE, 208V
Note: 72″H E Series enclosure can accept a maximum of 59″H power strips
Monitored
Monitored ePDU
• Monitors the amperage passing through each circuit of the ePDU
• Easy-read LED displays power usage, visible from up to 12 feet away
• Readings accessible via Ethernet connection over the network
PW102MI1U160 1.92 kW, L5-20P, 12 x 5-20R, 9′ cord, 1U rack mount,
1.80″H x 19.00″W x 7.00″D, 120V
PW105MI1U165 4.99 kW, L6-30P, 6 x C13/4 x C19, 9′ cord, 1U rack mount,
1.80″H x 19.00″W x 7.00″D, 208V
PW102MI0U235 1.92 kW, L5-20P, 24 x 5-20R, 9′ cord, vertical mount,
66.00″H x 1.90″W x 2.00″D, 120V
PW105MI0U240 4.99 kW, L6-30P, 24 x C13/4 x C19, 9′ cord, vertical mount
66.00″H x 1.90″W x 2.00″D, 208V
PW306MI0U245 5.86 kW, L21-20P, 30 x C13/6 x C19, 9′ cord, vertical mount
66.00″H x 1.90″W x 2.00″D, 3 phase WYE, 208V
PW309MI0U248 8.65 kW, L21-30P, 24 x C13/3 x C19/6 x 5-20R, 9′ cord, vertical mount
66.00″H x 1.90″W x 2.00″D
, 3 phase WYE, 120V + 208V
V55C39-60-3-109 17.29 kW, IEC 309-60, 24 x C13/12 x C19, 9′ cord, vertical mount
55.00″H x 3.50″W x 3.50″D, 208V
PW317MI0U222 17.29 kW,IEC  309-60, 12 x C13/12 x C19, 9′ cord, vertical mount
66.00″H x 2.00″W x 4.00″D, 208V
Note: 72″H E Series enclosure can accept a maximum of 59″H power strips
AdvMonitored
Advanced Monitored ePDU
• Monitors the amperage passing through each circuit of the ePDU
• Easy-read LED displays power usage, visible from up to 12 feet away
• Readings accessible via Ethernet connection over the network
• Supports remote, individual outlet level monitoring
VPC3695-3794 4.99 kW, L6-30P, 14 x C13/2 x C19, 9′ cord, vertical mount,
66.00″H x 2.00″W x 3.50″D, 208V
VPC3695-3792 8.65 kW, L21-30P, 21 x C13/3 x C19, 9′ cord, vertical mount,
66.00″H x 2.00″W x 3.50″D, 208V
Note: 72″H E Series enclosure can accept a maximum of 59″H power strips
Switched
Switched ePDU
• Monitors the amperage passing through each circuit of the ePDU
• Easy-read LED displays power usage, visible from up to 12 feet away
• Readings accessible via Ethernet connection over the network
PW102SW1U226 1.92 kW, L5-20P, 12 x 5-20R, 9′ cord, 1U rack mount,
1.80″H x 19.00″W x 7.00″D, 120V
PW105SW2U223 4.99 kW, L6-30P, 20 x C13/4 x C19, 9′ cord, 2U rack mount,
3.50″H x 19.00″W x 9.50″D, 208V
PW102SW0U151 1.92 kW, L5-20P, 24 x 5-15R, 9′ cord, vertical mount,
70.00″H x 1.90″W x 2.00″D, 120V
PW105SW0U230 4.99 kW, L6-30P, 20 x C13/4 x C19, 9′ cord, vertical mount
66.00″H x 1.90″W x 2.00″D, 208V
PW306SW0U231 5.86 kW, L21-20P, 20 x C13/4 x C19, 9′ cord, vertical mount
66.00″H x 2.00″W x 4.00″D, 208V
PW309SW0U178 8.65 kW, L21-30P, 24 x C13, 9′ cord, vertical mount
66.00″H x 2.00″W x 4.00″D, 208V
PW314SW0U232 14.4 kW, CS8365, 20 x C13/4 x C19, 9′ cord, vertical mount
66.00″H x 2.00″W x 4.00″D, 3 phase delta 50A, 208V
Note: 72″H E Series enclosure can accept a maximum of 59″H power strips
Temperature and Humidity Sensors
Optional temperature and humidity sensors connect to Monitored, Advanced Monitored and Switched ePDU  models to monitor environmental conditions within the data center.
SENSOR-T1-10 One Temperature Sensor, 10′ Cable
SENSOR-T2-10 Two Temperature Sensors, 10′ Cable each
SENSOR-T1H1-10 One Temperature and one Humidity Sensor, 10′ Cable
IPM_GlobeWithData
IPM_MainListView
IPM_ColumnSelection
Intelligent Power Manager Software
New Intelligent Power® Manager software from Eaton enables centralized monitoring and management of multiple networked power devices and environmental sensors from a single PC interface. Exceptionally versatile, this software maximizes system uptime by simplifying management, minimizing response time and reducing time to repair. Intelligent Power Manager is compatible with all ePDUs that feature Ethernet connections, including Monitored, Advanced Monitored and Switched models.
Features and Benefits
• User-definable tree structure enables grouping, access and management of multiple devices over multiple locations
• Alerts are sent via mobile phone and/or e-mail
• Shutdown agent enables safe, graceful shutdown of servers during an extended power failure
• Node asset management feature allows the data center manager to track the addition, movement and removal of equipment within the data center
• Multiple password-protected access levels ensure secure data communications
• Firmware management and auto discovery features simplify installation, set-up and maintenance

©2010 Great Lakes Case & Cabinet Co., Inc. | Contact Us at 1-866-TRY-GLCC