Geist is a US manufacturer of customized power distribution solutions for racks and cabinets. With the broadest selection in the industry, Geist offers over 1000 model numbers made up of numerous product configurations and options. All model numbers are built to order, allowing customers to build a PDU to fit their specific needs; these customized PDUs are still able to be pre-installed in Great Lakes enclosures.
 |
| PDU with Local Digital Read-Out |
| RBRCN100-102STL |
20 AMP, 125V, L5-20P, 10 x 5-20R on rear, 10′ cord, 1U rack mount,
1.72″H x 17.00″W x 4.50″D; Digital power meter displays amps, volts,
watts and power factor. |
| NSVBCN200-102S20TL |
20 AMP, 125V, L5-20P, 20 x 5-20R on rear, 10′ cord, vertical mount,
66.25″H x 1.61″W x 1.61″D; Digital power meter displays amps, volts,
watts and power factor. (pictured above) |
| Note: 72″H E Series enclosure can accept a maximum of 59″H power strips |

|
RacSense
RacSense® Power solutions feature power distribution units with remote power monitoring and
alarming. Monitors voltage, current, real power, apparent power & power factor. |
| RSPRN122-00C13C20 |
20 AMP, 125 or 250V, C20 power inlet (cord required), 12 x C-13
1U rack mount, 1.72″H x 17.00″W x 4.50″D (pictured above) |
| RSPBN302-102IN6TL5 |
20 AMP, 125V, L5-20P, 24 x C-13/6 x C19, 10′ cord, vertical mount,
66.25″H x 2.00″W x 2.00″D |
| Note: 72″H E Series enclosure can accept a maximum of 59″H power strips |

|
RacSense Master
RacSense® Master units combine power distribution, power/environmental monitoring, and remote
alarming together in one solution. Environmental monitoring via three I/O ports or using four RJ12 ports.
|
| RSMRN122-002C13C20 |
20 AMP, 125 or 250V, C20 power inlet (cord required), 8 x C-13,
1U rack mount, 1.72″H x 17.10″W x 8.50″D (connect optional remote
sensors via 2 x RJ jacks) (pictured above) |
| RSMB300-103IN6TL5 |
20 AMP, 125V, L5-20P, 16 x 5-15R, 10′ cord, vertical mount, 66.25″H x
3.10″ W x 2.00″D (connect optional remote sensors via 2 x RJ jacks) |
| Note: 72″H E Series enclosure can accept a maximum of 59″H power strips |
 
|
RacSense Control Ultra
RacSense® Control Ultra distribution units deliver individual on/off outlet control, receptacle level current
monitoring, user defined alarm thresholds and real-time remote alarming.
|
| RSURN082-002C13C20 |
20 AMP, 125 or 250V, C20 power inlet (cord required), 8 x C-13,
1U rack mount, 1.72″H x 17.10″W x 8.50″D (connect optional remote
sensors via 2 x RJ jacks) (pictured above) |
| RCUBN162-102S15TL5 |
20 AMP, 125V, L5-20P, 16 x 5-15R, 10′ cord, vertical mount, 66.25″H x
3.10″ W x 2.00″D (connect optional remote sensors via 2 x RJ jacks) |
| Note: 72″H E Series enclosure can accept a maximum of 59″H power strips |
 |
RacSense Control Ultra
Monitors up to 16 remote environmental sensors with a unit the size of a candy bar. This compact and powerful unit displays the same user interface, including graphs, as the
RacSense product line. Ideal for discrete placement in tight locations.
|
| RSMINI |
Mini Environmental Monitoring Unit to be used with the following parts: |
| RT12 |
Temperature Sensor, 12′ cord (RJ) |
| RTAF12 |
Temperature and Airflow Sensor, 12′ cord (RJ) |
| RTAFH12 |
Temperature, Airflow, and Humidity Sensor, 12′ cord (RJ) |
| RTHD12 |
Temperature, Humidity, and Dew Point Sensor, 12′ cord 9RJ) |
| RCP2 |
City Power Monitor |
| SA-1 |
Smoke Alarm Kit (I/O) |
| RWS |
Water Sensor, 20′ cord (I/O) |
| SP-5 RJ12 |
5 Way Splitter |
| CCAT |
I/O to RJ Remote Sensor Convertor |

With today’s rapidly evolving information technology and equipment—and 99.999% system availability requirements—data center IT managers need increasingly sophisticated power distribution solutions. Eaton® offers the largest selection of enclosure power distribution solutions on the market, including the Eaton ePDU™ product family. ePDUs are specifically designed to provide maximum flexibility and reliability in distributing power throughout modern data centers. They enable primary power distribution from the UPS to secondary power distribution devices or directly to IT equipment, for organized power distribution with fewer cables to manage and fewer distribution points to monitor.
Features and Benefits
• Data center- and server-level power measurement and control
• Basic, Monitored, Advanced Monitored and Switched models available to provide exactly the desired level of control
• High-density models for power-hungry IT equipment including blade servers and switches
• Vertical 0U or rack mount 1U/2U configurations for flexible installation
• Configurable combinations of NEMA, IEC and hardwired input connections, and NEMA and IEC output receptacles
• Circuit breaker or individual outlet fusing options
• Rugged, industrial-grade construction
• Wall, floor and rack mounting options
• North American and international configurations available
• Custom designs available on request
• Designed to meet global safety standards including UL and CE

|
Basic ePDU
• Reliable and economical enclosure power distribution
• Vertical and horizontal mounting capabilities
|
| PW102BA1U159 |
1.92 kW, L5-20P, 12 x 5-20R, 9′ cord, 1U rack mount,
1.80″H x 19.00″W x 7.00″D, 120V
|
| PW105BA1U192 |
4.99 kW, L6-30P, 6 x C13/4 x C19, 9′ cord, 1U rack mount,
1.80″H x 19.00″W x 7.00″D, 208V
|
| PW102BA0U021 |
1.92 kW, L5-20P, 24 x 5-20R, 15′ cord, vertical mount,
60.00″H x 2.10″W x 1.30″D, 120V
|
| PW105BA0U239 |
4.99 kW, L6-30P, 24 x C13/4 x C19, 9′ cord, vertical mount
66.00″H x 1.90″W x 2.00″D, 208V
|
| PW306BA0U244 |
5.86 kW, L21-20P, 30 x C13/6 x C19, 9′ cord, vertical mount
66.00″H x 1.90″W x 2.00″D, 3 phase WYE, 208V
|
| Note: 72″H E Series enclosure can accept a maximum of 59″H power strips |

|
Monitored ePDU
• Monitors the amperage passing through each circuit of the ePDU
• Easy-read LED displays power usage, visible from up to 12 feet away
• Readings accessible via Ethernet connection over the network
|
| PW102MI1U160 |
1.92 kW, L5-20P, 12 x 5-20R, 9′ cord, 1U rack mount,
1.80″H x 19.00″W x 7.00″D, 120V
|
| PW105MI1U165 |
4.99 kW, L6-30P, 6 x C13/4 x C19, 9′ cord, 1U rack mount,
1.80″H x 19.00″W x 7.00″D, 208V
|
| PW102MI0U235 |
1.92 kW, L5-20P, 24 x 5-20R, 9′ cord, vertical mount,
66.00″H x 1.90″W x 2.00″D, 120V
|
| PW105MI0U240 |
4.99 kW, L6-30P, 24 x C13/4 x C19, 9′ cord, vertical mount
66.00″H x 1.90″W x 2.00″D, 208V
|
| PW306MI0U245 |
5.86 kW, L21-20P, 30 x C13/6 x C19, 9′ cord, vertical mount
66.00″H x 1.90″W x 2.00″D, 3 phase WYE, 208V
|
| PW309MI0U248 |
8.65 kW, L21-30P, 24 x C13/3 x C19/6 x 5-20R, 9′ cord, vertical mount
66.00″H x 1.90″W x 2.00″D, 3 phase WYE, 120V + 208V |
| V55C39-60-3-109 |
17.29 kW, IEC 309-60, 24 x C13/12 x C19, 9′ cord, vertical mount
55.00″H x 3.50″W x 3.50″D, 208V
|
| PW317MI0U222 |
17.29 kW,IEC 309-60, 12 x C13/12 x C19, 9′ cord, vertical mount
66.00″H x 2.00″W x 4.00″D, 208V
|
| Note: 72″H E Series enclosure can accept a maximum of 59″H power strips |

|
Advanced Monitored ePDU
• Monitors the amperage passing through each circuit of the ePDU
• Easy-read LED displays power usage, visible from up to 12 feet away
• Readings accessible via Ethernet connection over the network
• Supports remote, individual outlet level monitoring
|
| VPC3695-3794 |
4.99 kW, L6-30P, 14 x C13/2 x C19, 9′ cord, vertical mount,
66.00″H x 2.00″W x 3.50″D, 208V
|
| VPC3695-3792 |
8.65 kW, L21-30P, 21 x C13/3 x C19, 9′ cord, vertical mount,
66.00″H x 2.00″W x 3.50″D, 208V
|
| Note: 72″H E Series enclosure can accept a maximum of 59″H power strips |

|
Switched ePDU
• Monitors the amperage passing through each circuit of the ePDU
• Easy-read LED displays power usage, visible from up to 12 feet away
• Readings accessible via Ethernet connection over the network
|
| PW102SW1U226 |
1.92 kW, L5-20P, 12 x 5-20R, 9′ cord, 1U rack mount,
1.80″H x 19.00″W x 7.00″D, 120V
|
| PW105SW2U223 |
4.99 kW, L6-30P, 20 x C13/4 x C19, 9′ cord, 2U rack mount,
3.50″H x 19.00″W x 9.50″D, 208V
|
| PW102SW0U151 |
1.92 kW, L5-20P, 24 x 5-15R, 9′ cord, vertical mount,
70.00″H x 1.90″W x 2.00″D, 120V
|
| PW105SW0U230 |
4.99 kW, L6-30P, 20 x C13/4 x C19, 9′ cord, vertical mount
66.00″H x 1.90″W x 2.00″D, 208V
|
| PW306SW0U231 |
5.86 kW, L21-20P, 20 x C13/4 x C19, 9′ cord, vertical mount
66.00″H x 2.00″W x 4.00″D, 208V
|
| PW309SW0U178 |
8.65 kW, L21-30P, 24 x C13, 9′ cord, vertical mount
66.00″H x 2.00″W x 4.00″D, 208V
|
| PW314SW0U232 |
14.4 kW, CS8365, 20 x C13/4 x C19, 9′ cord, vertical mount
66.00″H x 2.00″W x 4.00″D, 3 phase delta 50A, 208V
|
| Note: 72″H E Series enclosure can accept a maximum of 59″H power strips |
Temperature and Humidity Sensors
Optional temperature and humidity sensors connect to Monitored, Advanced Monitored and Switched ePDU models to monitor environmental conditions within the data center.
|
| SENSOR-T1-10 |
One Temperature Sensor, 10′ Cable |
| SENSOR-T2-10 |
Two Temperature Sensors, 10′ Cable each |
| SENSOR-T1H1-10 |
One Temperature and one Humidity Sensor, 10′ Cable |


 |
Intelligent Power Manager Software
New Intelligent Power® Manager software from Eaton enables centralized monitoring and management of multiple networked power devices and environmental sensors from a single PC interface. Exceptionally versatile, this software maximizes system uptime by simplifying management, minimizing response time and reducing time to repair. Intelligent Power Manager is compatible with all ePDUs that feature Ethernet connections, including Monitored, Advanced Monitored and Switched models.
Features and Benefits
• User-definable tree structure enables grouping, access and management of multiple devices over multiple locations
• Alerts are sent via mobile phone and/or e-mail
• Shutdown agent enables safe, graceful shutdown of servers during an extended power failure
• Node asset management feature allows the data center manager to track the addition, movement and removal of equipment within the data center
• Multiple password-protected access levels ensure secure data communications
• Firmware management and auto discovery features simplify installation, set-up and maintenance |