ES Frames
- Welded frame with two pairs of 19" EIA mounting rails with RMU markings and FMP (3/8" sq. (M6) rails installed; choose tapped #10-32 at no charge) and two pairs of PDU brackets to accept vertical cable troughs (VCT), vertical cable bars (VCB), and/or PDUs
- 19" EIA 310-E Compliant
- UL Total Rail Rating, 3300 lbs.; Total Max Static Weight, 4000 lbs.
- Ideal for servers and multiple data center configurations
- Rails fully adjustable front to rear
- Knockouts on top, bottom, and sides of frame
- PDU brackets that allow mounting of PDUs and vertical cable troughs
- Supports overhead cabling needs with ladder rack brackets and cable troughs (optional)
- Supports cooling needs with exhaust chimneys, air managers, and more
Part No. | Description |
---|---|
9101ES-3048 | 91"H x 30"W x 48"D, 48 RMU ES Frame |
9101ES-3042 | 91"H x 30"W x 42"D, 48 RMU ES Frame |
9101ES-2448 | 91"H x 24"W x 48"D, 48 RMU ES Frame |
9101ES-2442 | 91"H x 24"W x 42"D, 48 RMU ES Frame |
8401ES-3248 | 84"H x 32"W x 48"D., 44 RMU ES Frame |
8401ES-3242 | 84"H x 32"W x 42"D, 44 RMU ES Frame |
8401ES-3240 | 84"H x 32"W x 40"D, 44 RMU ES Frame |
8401ES-3048 | 84"H x 30"W x 48"D, 44 RMU ES Frame |
8401ES-3042 | 84"H x 30"W x 42"D, 44 RMU ES Frame |
8401ES-2448 | 84"H x 24"W x 48"D, 44 RMU ES Frame |
8401ES-2442 | 84"H x 24"W x 42"D, 44 RMU ES Frame |
7901ES-3048 | 79"H x 30"W x 48"D, 42 RMU ES Frame |
7901ES-3042 | 79"H x 30"W x 42"D, 42 RMU ES Frame |
7901ES-2448 | 79"H x 24"W x 48"D, 42 RMU ES Frame |
7901ES-2442 | 79"H x 24"W x 42"D, 42 RMU ES Frame |
4801ES-2442 | 48"H x 24"W x 42"D, 24 RMU ES Frame |

E Series Frames
- Welded frame with two pairs of 19" EIA mounting rails with RMU markings and FMP; 3/8" sq. (M6) rails installed; choose tapped #10-32 at no charge
- 19" EIA 310-E Compliant
- UL Total Rail Rating, 1500 lbs.; Total Max Static Weight, 2500 lbs. (except where noted)
- Ideal for networking, telecom, and server applications
- Rails fully adjustable front to rear
- Multiple cooling accessories available: 19" fan trays, fan top panels, and more
- Optional lacing bars and 19" cable organizers
Part No. | Description |
---|---|
8401E-2936 | 84"H x 29"W x 36"D, 44 RMU E Frame |
8401E-2932 | 84"H x 29"W x 32"D, 44 RMU E Frame |
8401E-2436 | 84"H x 24"W x 36"D, 44 RMU E Frame |
8401E-2432 | 84"H x 24"W x 32"D, 44 RMU E Frame |
7201E-2936 | 72"H x 29"W x 36"D, 37 RMU E Frame |
7201E-2932 | 72"H x 29"W x 32"D, 37 RMU E Frame |
7201E-2436 | 72"H x 24"W x 36"D, 37 RMU E Frame |
7201E-2432 | 72"H x 24"W x 32"D, 37 RMU E Frame |
6001E-2432 | 60"H x 24"W x 32"D, 31 RMU E Frame; UL Rail Rating/Max Static Weight, 600 lbs. |
4801E-2432 | 48"H x 24"W x 32"D, 21 RMU E Frame; UL Rail Rating/Max Static Weight, 600 lbs. |
3001E-2432 | 30"H x 24"W x 32"D, 13 RMU E Frame; UL Rail Rating/Max Static Weight, 600 lbs. |
Below is a sampling of our most popular custom colors and finishes. These colors may require a longer lead time and special pricing. Please call 1.866.TRY. GLCC for more information on custom colors and textures.
Note: Color represented may not be completely accurate based on your individual computer monitors.

P02-051: GLOSS WHITE

WINTER WHITE (P02-047: SEMI-GLOSS TEXTURED)

P02-045: STANDARD ADVANTAGE WHITE TEXTURE

P02-001: BEIGE TEXTURE

P02-050: HAMMERTONE BEIGE

P04-001: SMOOTH GRAY

P02-059: SEMI-GLOSS TEXTURE GRAY

P02-039: SMOOTH SILVER (CHROME)

P02-069: SEMI-GLOSS HAMMERTONE SILVER

P06-052: TEXTURED RED

P02-005: STANDARD NITRO BLUE

P02-076: POLYESTER PMS BLUE

P02-068: SEMI-GLOSS HAMMERTONE BLUE

P06-051: TEXTURED GRAPE

P02-082: TEXTURE VIOLET
ES Enclosures come with a universal power strip bracket set in both rear corners. These bracket sets will accept a wide range of PDUs and will also accept vertical cable troughs (VCT-78/VCT-84). The drawing shows the usable mounting space in 42"D enclosures. A combination of PDUs and VCTs can be mounted; however, the size of the PDU will determine how many of each you will be able to place on the brackets. Keep in mind that VCTs are 3"W. The location of the button mounting will also need to be taken into consideration when placing your PDUs.

ES Enclosures come with a universal power strip bracket set in both rear corners. These bracket sets will accept a wide range of PDUs and will also accept vertical cable troughs (VCT-78/VCT-84). The drawing shows the usable mounting space in 48"D enclosures. A combination of PDUs and VCTs can be mounted; however, the size of the PDU will determine how many of each you will be able to place on the brackets. Keep in mind that VCTs are 3"W. The location of the button mounting will also need to be taken into consideration when placing your PDUs.